The Positector 6000 High-Range Probes are ideal for thick protective coatings, such as epoxy, rubber, concrete liners, intumescent fireproofing, ship hull coatings (FNGS) and more.
Features
Technical Attributes
Probe Model | FTS | FTRS | FNTS | FKS | NKS | FJS | FLS | FNGS |
Substrates: | Ferrous | Ferrous | Ferrous / Non-ferrous | Ferrous | Non-Ferrous | Ferrous | Ferrous | Ferrous / Non-Ferrous |
Range: | 0 - 250 mils (0 - 6 mm / 0 - 6000 µm) | 0 - 500 mils (0 - 13 mm) | 0 - 1.0 in. (0 - 25 mm) | 0 - 1.5 in. (0 - 38 mm) | 0 - 2.5 in. (0 - 63.5 mm) | |||
Accuracy: | ±(0.5 mils + 1%) 0 - 100 mils ±(0.5 mils + 3%) > 100 mils ±(0.01 mm + 1%) 0 - 25 mm ±(0.01 mm + 3%) > 2.5 mm | ±(1 mils + 3%) 0 - 500 mils ±(0.02 mm + 3%) 0 - 13 mm | ±(0.01 mils + 3%) ±(0.2 mm + 3%) | ±(0.01 in. + 3%) ±(0.2 mm + 3%) | ±(0.01 in. + 3%) ±(0.2 mm + 3%) | |||
Calibration Standards: | P1 | P5 | P2 | P8 | ||||
Minimum Surface Area: | - | 3.23 x 3.25 in. (83 x 83 mm) | 10 x 10 in. (254 x 254) | |||||
Minimum Substrate Thickness: | - | 0.1 in. (2.5 mm) | 0.2 in. (5 mm) | |||||
Weight: | - | 0.8 lb. (0.4 kg) | ||||||
Accuracies are stated as a fixed value plus a percentage of the gage's actual reading |