Features
Technical Attributes
Models: | 15308 (Method A) | 12953 (Method A/B) |
Mode of Operation: | Off-line testing / lab use | |
Materials: | All sheet materials | |
Test Method Drop Height: | 26 in. (66 cm) | 26 in. (66 cm) and 60 in. (152 cm), adjustable |
Actuation Method: | Electronic | |
Dart Release Mechanism: | Pneumatic | |
Sample Clamp Mechanism: | Pneumatic | |
Dart Weight Sets Included: | Method A - (412 gram): (2) 120 gr., (1) 60 gr., (1) 30 gr., (2) 15 gr., (2) 5 gr. | Method A - (412 gram): (2) 120 gr., (1) 60 gr., (1) 30 gr., (2) 15 gr., (2) 5 gr. Method B - (1310 gram), (2) 320 gr., (1) 160 gr., (1) 80 gr., (2) 40 gr., (2) 15 gr. |
Optional Weights: (ASTM D1709 Suggested for Staircase Test Method) | Method A - (8) 60 gr., (8) 30 gr., (8) 15 gr., (2) 5 gr. | Method A - (8) 60 gr., (8) 30 gr., (8) 15 gr., (2) 5 gr. Method B - (8) 90 gr., (8) 45 gr., (2) 15 gr. |
Dart Head Material Provided (Standard): | Phenolic (Method A) | Phenolic (Method A) / Stainless (Method B) |
Optional Dart Head Materials: | Aluminum | Aluminum/Stainless Steel |
Air Requirements: | 60 psi / Dry & Filtered | |
Power Requirements: | 115 VAC / 60 Hz or 230 VAC / 50 Hz | |
Overall Height: | 48 inch (Method A) | 80 inch (Method A and B) |
Weight: | 55 lb (Method A) | 65 lb (Method A and B) |
(Due to continuous product improvement, all specifications are subject to change without notice.) |
Standards
Meets ASTM D1709 Methods A & A/B Standard Test Method for Free Falling Dart Impact Testing of Plastic Film.
Delivery Content
Dart Drop Tester, Method A (26") includes 412 gr. Method A Dart Head/Stem/Weights/Collar Set, Dart Set - (412 gram): (2) 120 gr., (1) 60 gr., (1) 30 gr., (2) 15 gr., (2) 5 gr.
Accessories
Other Variations