Features
Technical Attributes
Application/Use: | Budget option for general paint and powder |
Software: | EasyTrack Insight Standard or Professional |
Thermal Barrier: | 2 hrs @ 200°C (392°F) |
General Information | |
Channels: | 4 or 6 thermocouple options |
Measurement Range: | -238 to 932°F (-150 to 500°C) |
Thermocouple Type: | K (mini-plug) |
Logger Accuracy: | ±0.9°F (±0.5°C) |
Cold Junction Compensation: | Accuracy guaranteed with change in logger temperature |
Resolution: | ±0.2°F (±0.1°C) |
Logger Operating Range: | 32 to 185°F (0 to 85°C) with safe auto shut down |
Case: | High temperature cool touch molded polycarbonate <212°F (100°C) |
PCB: | Coated to improve moisture protection |
Sampling Interval: | 0.5 s to 60min |
Start Trigger: | Auto start/ start button / temperature trigger |
Battery Use: | Replaceable 9V alkaline (ANSSI/NEDA 1604A IEC6LR61) |
Battery Life: | Min 360 hours continuous operation - 5 s, 6 channels 77°F (25°C) Min 50x1 hour oven runs - 5 s, 6 channels at 158°F (70°C) |
Memory: | 18.000 readings per channel per run (0.5 s sample interval = 2.5 hours run time). Non volatile hot data protection. |
On Board Calibration Data: | Digital certificate |
On Board Logger LEDs: | Logger & battery status indication |
On Board Logger Diagnostics: | Service email for logger health check |
Logger USB Power: | No battery discharge on reset & download |
Auto Logger Detection: | Auto boot up when logger detected by Insight™ software |
Multiple Run Capability*: | Max 3 runs separately stored in logger |
SmartPaq*: | Intelligent logger profile run "pass/fail" indicator |
Computer Interface Cable: | CI1150 mini-B USB connector |
Hardwired Telemetry: | via USB cable |
Software Compatibility: | EasyTrack Insight (V8.50); EasyTrack Insight Professional (V8.50) |
Windows Compatibility: | 32 and 64-bit versions of Windows® XP, Vista, 7, 8, 10 |
Logger Dimension (lxwxh): | 170 x 67 x 20.5mm (6.7 x 2.6 x 0.8 in) |
Replaces: | EasyTrack; EasyTrack2 |
Logger Weight: | 4 Channel - 196 g (0.43 lbs); 6 Channel - 200 g (0.44 lbs) |
Probe Options | |
Ambient Air Clamp: | (Maximum temperature reading of 510°F/265°C) - These probes are designed specifically for measuring ambient air temperature. They are constructed with a stainless steel outer tube with a Teflon core, stainless steel clip and an exceptionally durable, quadruple wrapped, ten strand PTFE coated wire. |
Magnetic Surface: | (Maximum temperature reading of 510°F/265°C) - Small, yet extremely strong, these new probes give accurate and repeatable temperature readings in the tightest of recesses. with a 0.7” (17mm) footprint, state-of-the-art magnets, and an easy to grasp aluminum handle. |
Magnetic Ambient Air: | (Maximum temperature reading of 510°F/265°C) - These probes are designed specifically for measuring ambient air temperature. They are constructed with a stainless steel outer tube, and an exceptionally durable quad wrapped, 10 strand PTFE coated wire. |
MicroMag Surface & Air: | With a 17mm (0.7”) state of the art Samarium Cobalt magnet, low thermal mass and an easy to handle aluminum knob, the MicroMag can be quickly and efficiently attached to ferrous substrates. Despite its compact size, the magnet strength guarantees secure attachment at the highest temperatures experienced within the paint and powder coating industry. The MicroMag is useful in extremely tight places. |
Rapid Response Heavy Duty Patch: | These probes are recommended for non-ferrous substrates such as plastic or aluminum. The welded thermocouple junction allows for a rapid response time of 1 sec. They are attached to the test piece by spot-welding, soldering or use of high temperature tape. These probes can also be used in still air environments as a rapid response ambient air probe. |
* Requires Insight Professional software |
Delivery Content
4 Channel Data Logger, Thermal Barrier w/Heat Sink, EasyTrack Insight Software, (2) 9V Batteries, Manual, Quick Reference Guide
Accessories