Features
Technical Attributes
Type: | GM | FM | S3M | S10M | ZN/FE |
Range: | 0 - 4 mils | 0 - 40 mils | 8 - 120 mils | .1 - .4 inch | 0 - 2.2 oz/ft.2 |
Application: | Electroplating and thin paint coatings on steel (ST 33 to ST 60) | Paint on steel (ST 33 to ST 60) | Enamel, plastic and rubber on steel (ST 33 to ST 60) | Electrolytic and Hot-Dip Galvanized over Steel | |
Tolerance: | ±.04 mils or 5% of the reading | ±.2 mils or 5% of the reading | ± 5% of the reading | ± 5% of the reading | .025 oz./ft.2 or 5% of the reading |
Minimum Surface: | .8" dia. | 1.2" dia. | 1.2" dia. | 4" dia. | .8 inch dia. |
Min Curvature Radius of the Samples: | .2" convex/ 1" concave | .32" convex/ 1" concave | .6" convex/ 1" concave | .8" convex/ 1" concave | - |
Min Base Thickness: | .040" | .040" | .060" | .080" | .040" |
Ambient Temperature: | -4°F - 212°F (-20°C - 100°C) | ||||
Dimensions: | Gauge - 8.5"x 2.2"x1.2" (215 mm x 55 mm x 29 mm) Plastic carrying case - 9.3"x3.4"x1.8" (235 mm x 185 mm x 46 mm) | ||||
Weight: | 1lb (560 g) |
Standards
All instruments conform to national and international standards: DIN EN ISO 2178, DIN 50982, ASTM B 499, E 376, D 1186, G 12, B 530, BS 5411, ISO 2361
Procedure
The measurement of the coating thickness is based on magnetic attraction. The attractive force is related to the distance between a permanent magnet and a steel substrate. This distance represents the thickness of the coating to be measured. The magnet is lifted from the surface by means of a spring connected to the magnet arm. The force needed to lift the magnet is directly related to the angle of rotation of the torsion spring. This measuring principle is also especially suited for electroplated nickel on copper, aluminium and other non-ferrous metals.
Automatic Mikrotest - Before measuring the scale wheel is turned as far as it will go and once started the built-in locking mechanism automatically carries out the process of measurement.
Downloads
Other Variations